Search results for "Nuclear Energy and Engineering"
showing 10 items of 596 documents
Choice of the detectors for light impurities plasma studies at W7-X using ‘CO Monitor’ system
2019
Abstarct The ‘CO Monitor’ is a new spectrometer system dedicated for the continuous measurements of line intensities of carbon, oxygen, boron and nitrogen at the fusion plasma experiment Wendelstein 7-X (W7-X). Its main purpose is to deliver constant information about indicated elements with high time resolution (better than 1 ms), but low spatial resolution since the line shapes are not going to be investigated. The system consists of four independent channels, each equipped with dispersive element dedicated for measurement of selected line of interest. In order to perform the highest efficiency of the ‘CO Monitor’ system, it is essential to choose the proper detector type for this task. T…
A comparative study on the compatibility of liquid lead–gold eutectic and liquid lead–bismuth eutectic with T91 and SS 316LN steels
2012
Abstract Liquid lead–gold eutectic (LGE) is considered as a potential target material for high power spallation sources. In the present work, the corrosion effects of LGE on T91 and SS 316LN steels have been investigated in comparison with that of liquid lead–bismuth eutectic (LBE) under the same testing conditions. Two tests were conducted at 400 °C for 1800 h and at 450 °C for 1300 h, in which specimens of the two steels were exposed to 1 m/s flowing LGE and LBE. Surface inspections showed that the specimens underwent a mixed corrosion mode of dissolution and oxidation. The results obtained from the SS 316LN specimens are very interesting. Firstly, EDX (electron energy dispersion X-ray sp…
Comparison of Single Event Transients Generated at Four Pulsed-Laser Test Facilities-NRL, IMS, EADS, JPL
2012
Four pulsed-laser single-event effects systems, differing in wavelength and pulse width, were used to generate single event transients in a large-area silicon photodiode and an operational amplifier (LM124) to determine how transient amplitude and charge collection varied among the different systems. The optical wavelength and the focused spot size are the primary factors influencing the resultant charge density profile. In the large-area photodiode the transients can be distorted by high charge-injection densities that occur for tightly focused, higher energy optical pulses. When the incident laser-pulse energies are corrected for reflection losses and photon efficiency, with collection de…
Mechanisms of Electron-Induced Single-Event Upsets in Medical and Experimental Linacs
2018
In this paper, we perform an in-depth analysis of the single-event effects observed during testing at medical electron linacs and an experimental high-energy electron linac. For electron irradiations, the medical linacs are most commonly used due to their availability and flexibility. Whereas previous efforts were made to characterize the cross sections at higher energies, where the nuclear interaction cross section is higher, the focus of this paper is on the complete overview of relevant electron energies. Irradiations at an electron linac were made with two different devices, with a large difference in feature size. The irradiations at an experimental linac were performed with varying en…
Effects of magnetic configuration on hot electrons in a minimum-B ECR plasma
2020
International audience; To investigate the hot electron population and the appearance of kinetic instabilities in highly charged electron cyclotron resonance ion source (ECRIS), the axially emitted bremsstrahlung spectra and microwave bursts emitted from ECRIS plasma were synchronously measured on SECRAL-II (Superconducting ECR ion source with Advanced design in Lanzhou No. II) ion source with various magnetic field configurations. The experimental results show that when the ratio of the minimum field to the resonance field (i.e. Bmin/Becr ) is less than ~0.8, the bremsstrahlung spectral temperature Ts increases linearly with the Bmin/Becr –ratio when the injection, extraction and radial mi…
The role of radio frequency scattering in high-energy electron losses from minimum-B ECR ion source
2021
Abstract The measurement of the axially lost electron energy distribution escaping from a minimum-B electron cyclotron resonance ion source in the range of 4–800 keV is reported. The experiments have revealed the existence of a hump at 150–300 keV energy, containing up to 15% of the lost electrons and carrying up to 30% of the measured energy losses. The mean energy of the hump is independent of the microwave power, frequency and neutral gas pressure but increases with the magnetic field strength, most importantly with the value of the minimum-B field. Experiments in pulsed operation mode have indicated the presence of the hump only when microwave power is applied, confirming that the origi…
Regulating blockchain for sustainability? The critical relationship between digital innovation, regulation, and electricity governance
2021
Abstract Blockchain technology has found several innovative applications in the electricity industry. However, its potential has still to be discovered. This is partly due to the role that regulation plays in electricity markets. To be introduced, experimented with, and eventually adopted on a commercial scale, blockchain-supported innovations need to fit the existing regulatory framework or the rules to be reshaped or updated. We focus on energy regulators' possible responses to the blockchain-enhanced market operations (both from the incumbents and potential newcomers), suggesting a monitoring mechanism that can support innovation.
Measurement and Prediction of Centrifugal Compressor Axial Forces During Surge—Part II: Dynamic Surge Model
2017
The force acting on centrifugal compressors is an important parameter to be considered throughout the operating life of these turbomachines. When the compressor is operating in surge conditions, these forces can become highly dangerous for the mechanical and aerodynamic structures. This instability is usually avoided in industrial applications, but the antisurge system may not react in time when emergency shutdowns or power failures take place. During these rapid transients, surge can develop, generating unsteady forces which can harm the close clearance components of the compressor. Therefore, the capability to predict the characteristics and the dynamics of these surge forces would allow …
An experimental search for a correlation between outdoor 222Rn concentration and 210Pb activity in air particulate samples
2018
This work was aimed to search for a correlation between outdoor 222Rn air concentration and 210Pb activity in particulate samples collected on a filter. The existence of a correlation could support the hypothesis that both 222Rn and its long-lived product 210Pb are embedded into the same air masses and undergo the same air transport phenomena. Lead-210 activity was determined by means of gamma ray spectrometric measurement carried out a few days after the sampling whereas 222Rn concentration was measured through a commercial monitor. Experimental tests allowed to obtain a weak correlation between 222Rn and 210Pb air concentration as a preliminary result due to high uncertainties of outdoor …
Estimation of the committed radiation dose resulting from gamma radionuclides ingested with food
2014
The objective of the study was to estimate the value of the radiation dose absorbed in consequence of consumption of popular food products for individual age groups. Potatoes, corn and sugar beet were selected for the study. Edible parts of these plants were collected in experimental fields of the KWS Lochow Polska Sp. z o.o. seeding company in Kondratowice (Poland). On the basis of the obtained study results, it can be stated that in consequence of consumption of the selected food products, people may receive increased doses from both natural and artificial radioactive isotopes. The doses calculated for several age groups do not show any health hazards in consequence of consumption of the …